Everything below concerns Lyophilized powder. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Updated 2026-06-26. Numbers and descriptions here follow the published literature rather than marketing material.
Routine characterization relies on reversed-phase high-performance liquid chromatography to establish purity and on mass spectrometry to confirm molecular identity. Electrospray ionization and matrix-assisted laser desorption ionization are both used for mass verification. Amino acid analysis and peptide mapping can detect sequence errors. Common impurities include truncated sequences, methionine sulfoxide formed by oxidation, and deamidated products. Chromatograms are usually recorded near 214 nm, where the peptide backbone absorbs, and purity is reported as the percentage area of the principal peak.
Verification of a supplied batch generally combines a certificate of analysis with independent testing, because certificates are self-reported documents. A typical package includes a chromatographic trace, a mass spectrum, and a stated water or counter-ion content. Batch-to-batch consistency matters more than a single purity figure when results are compared across experiments. No single mandatory standard governs research-grade peptide release, so laboratories are expected to define their own acceptance criteria. Residual trifluoroacetate from purification is a frequently overlooked counter-ion.
Lyophilized material is chemically stable for extended periods when kept dry, cold, and protected from light. The powder is hygroscopic, so vials should be warmed to room temperature before opening to reduce condensation on the contents. Once dissolved, the peptide is far less stable because peptide bonds are susceptible to hydrolysis and the methionine residue can oxidize. Solutions are typically aliquoted and held at 2-8 °C for short intervals or frozen for longer ones, and repeated freeze-thaw cycles should be avoided.
Development took place during the 1980s at institutes of the Russian Academy of Sciences, where peptide fragments of ACTH were screened for cognitive and neuroprotective effects. The compound received regulatory approval in Russia as a nasal preparation, marketed for conditions such as ischemic stroke, transient ischemic attacks, and optic nerve disorders. Registration in other countries has not followed. Most published clinical reports originate from a small number of Russian research groups, and independent replication outside that setting remains limited. The regulatory status therefore differs sharply between Russia and the rest of the world.
Laboratory work points toward modulation of neurotrophic signaling, particularly expression of brain-derived neurotrophic factor and nerve growth factor in hippocampal tissue. Studies also describe effects on monoamine turnover, inflammatory mediators, and oxidative markers. These observations come mainly from animal models and cultured cells, so the causal chain in humans is not firmly established. Whether the reported molecular changes translate into measurable clinical benefit is an open question. Reviews generally present the mechanism as plausible rather than demonstrated.
| Property | Value | Notes |
|---|---|---|
| Typical purity | 95% or higher | By reversed-phase HPLC area |
| Identity method | Electrospray mass spectrometry | Confirms molecular mass |
| Purity method | Reversed-phase HPLC | Detection near 214 nm |
| Primary degradation | Methionine oxidation | Sulfoxide product, +16 Da |
| Solution storage | 2-8 °C, short term | Aliquot to avoid freeze-thaw |
Practical handling follows from those properties. Bulk material is best divided into single-use portions soon after receipt, because each thaw exposes the whole container to moisture and temperature cycling. Vials should be allowed to reach room temperature before opening to prevent condensation on the powder. Low-binding plasticware reduces loss of dilute solutions, and sterile filtration is used when a preparation must remain free of microbial growth. Records of batch number, reconstitution date and storage history are what allow a later analytical result to be interpreted meaningfully.
Identity and purity of Semax are established mainly by reversed-phase high-performance liquid chromatography coupled with mass spectrometry. The chromatographic trace gives a purity estimate as a percentage of total peak area, while electrospray or matrix-assisted laser desorption ionization confirms the molecular mass against the calculated value. Amino acid analysis and sequence-specific fragmentation provide further confirmation when a supplier's chain of custody is unclear. Vendors frequently quote a purity figure without stating the detection wavelength or the integration method, which limits how far one number can be compared with another.
The parent fragment ACTH(4-10) carries the sequence Met-Glu-His-Phe-Arg-Trp-Gly. Semax replaces the arginine and tryptophan positions with a proline-glycine-proline tail, giving Met-Glu-His-Phe-Pro-Gly-Pro. That change removes residues associated with adrenal stimulation, so the peptide does not drive cortisol release the way full ACTH does. This distinction shapes how the compound is grouped in the literature, where it sits with neuropeptides and peptide neuromodulators rather than with corticosteroids.
Regulatory status varies sharply by country. Semax is registered for medical use in Russia, where it appears in formularies as a nasal solution, and it also holds registration in a small number of neighbouring states. It has no approval from the United States Food and Drug Administration or the European Medicines Agency, and it is not a scheduled controlled substance in most jurisdictions. Elsewhere it circulates mainly as laboratory material, so purity documentation comes from suppliers rather than from a national pharmacopoeia.
Semax is a synthetic peptide created in the Soviet Union during the early 1980s by researchers working in Moscow. It was built from the short adrenocorticotropic hormone fragment known as ACTH(4-10), and the chain was then extended with three additional amino acids. The resulting molecule was named semax and entered clinical use in Russia in 1994. It is generally described as a nootropic and neuroprotective agent rather than as a hormone analogue.
从分子层面看,Semax 是线性七肽,没有二硫键、糖基或脂链修饰,N 端为游离氨基,C 端为游离羧基。分子含组氨酸与谷氨酸侧链,因此在水和甲醇等极性溶剂中溶解良好,在非极性溶剂中溶解有限。计算分子量约为 814 Da,与其质子化离子的质荷比吻合,可用于质谱确认。
稳定性主要由水解与氧化两条路径支配。肽键在中性或弱酸性条件下相对稳定,遇到强碱或长时间高温则明显断裂;甲硫氨酸侧链容易被氧化成亚砜,使主峰前移并拉低实际含量。金属离子、光照和反复冻融会进一步促进降解或聚集。冻干粉在低温避光条件下可存放较长时间,配制后的水溶液通常需要冷藏并尽快用完。
Clinical reports describe use in ischaemic stroke, transient ischaemic attack, optic nerve conditions, and cognitive complaints, but most of these studies are small and were conducted in a single region. Systematic reviews have generally described the evidence base as limited in size and variable in methodological quality. Randomised controlled data suitable for international regulatory assessment are scarce. As a result, major treatment guidelines outside Russia do not include the peptide, and interest in it remains largely research-driven rather than routine clinical.
Semax is a synthetic heptapeptide with the sequence Met-Glu-His-Phe-Pro-Gly-Pro. It is described in the literature as an analogue of the ACTH(4–10) fragment, a short N-terminal portion of adrenocorticotropic hormone that retains some neurotropic activity without the full hormonal effects of the parent peptide. The molecule carries a methionine residue at the N-terminus and two proline residues near the C-terminus, features that shape both its interactions with receptor systems and its chemical stability. The free peptide corresponds to the formula C37H51N9O10S and a molecular mass near 813.9 Da.
The compound was developed in the 1980s at the Institute of Molecular Genetics in Moscow, where it emerged from research on short ACTH fragments and their effects on the central nervous system. Russian pharmaceutical listings describe it as a nootropic and neuroprotective agent, most often formulated as nasal drops. It is not a marketed medicine in the United States or the European Union, and no pharmacopoeial monograph covers it. Consequently, most published clinical experience with the substance originates from a small number of research centres, mainly in Russia and neighbouring countries.
== Pathovars == Following ribotype analysis, incorporation of several pathovars of P. syringae into other species was proposed (see P. amygdali, 'P. tomato', P. coronafaciens, P. avellanae, 'P. helianthi', P. tremae, P. cannabina, and P. viridiflava). According to this schema, the remaining pathovars are:
== History == Naltrexone was first synthesized in 1963 by Metossian at Endo Laboratories, a small pharmaceutical company in New York City. It was characterized by Blumberg, Dayton, and Wolf in 1965 and was found to be an orally active, long-acting, and very potent opioid antagonist. The drug showed advantages over earlier opioid antagonists such as cyclazocine, nalorphine, and naloxone, including its oral activity, a long duration of action allowing for once-daily administration, and a lack of dysphoria, and was selected for further development. It was patented by Endo Laboratories in 1967 under the developmental code name EN-1639A and Endo Laboratories was acquired by DuPont in 1969. Clinical trials for opioid dependence began in 1973, and a developmental collaboration of DuPont with the National Institute on Drug Abuse for this indication started the next year in 1974. The drug was approved by the FDA for the oral treatment of opioid dependence in 1984, with the brand name Trexan, and for the oral treatment of alcohol dependence in 1995, when the brand name was changed by DuPont to Revia. A depot formulation for intramuscular injection was approved by the FDA under the brand name Vivitrol for alcohol dependence in 2006 and opioid dependence in 2010.
==== Supercritical drying ==== To dry the gel, while preserving the highly porous network of an aerogel, supercritical drying employs the use of the liquid-gas transition that occurs beyond the critical point of a substance. By using this liquid-gas transition that avoids crossing the liquid-gas phase boundary, the surface tension that would arise within the pores due to the evaporation of a liquid is eliminated, thereby preventing the collapse of the pores. Through heating and pressurization, the liquid solvent reaches its critical point, at which point the liquid and gas phases become indistinguishable. Past this point, the supercritical fluid is converted into the gaseous phase upon an isothermal de-pressurization. This process results in a phase change without crossing the liquid-gas phase boundary. This method is proven to be excellent at preserving the highly porous nature of the solid network without significant shrinkage or cracking. While other fluids have been reported for the creation of supercritically dried aerogels, scCO2 is the most common substance with a relatively mild supercritical point at 31 °C and 7.4 MPa. CO2 is also relatively non-toxic, non-flammable, inert, and cost-effective when compared to other fluids, such as methanol or ethanol. While being a highly effective method for producing aerogels, supercritical drying takes several days, requires specialized equipment, and presents significant safety hazards due to its high-pressure operation.
=== Pay-off phase === The second half of glycolysis is known as the pay-off phase, characterised by a net gain of the energy-rich molecules ATP and NADH. Since glucose leads to two triose sugars in the preparatory phase, each reaction in the pay-off phase occurs twice per glucose molecule. This yields 2 NADH molecules and 4 ATP molecules, leading to a net gain of 2 NADH molecules and 2 ATP molecules from the glycolytic pathway per glucose.
Aluminium is extracted by dissolving its oxide Al2O3 in molten cryolite Na3AlF6 and then by high temperature electrolytic reduction. Selenium is produced by roasting the coinage metal selenides X2Se (X = Cu, Ag, Au) with soda ash to give the selenite: X2Se + O2 + Na2CO3 → Na2SeO3 + 2 X + CO2; the selenide is neutralized by sulfuric acid H2SO4 to give selenous acid H2SeO3; this is reduced by bubbling with SO2 to yield elemental selenium. Polonium and astatine are produced in minute quantities by irradiating bismuth.
Sources: en.wikipedia.org
The polypeptide hormone IGF1 is synthesized primarily in the liver upon stimulation by growth hormone (GH). It is a key mediator of anabolic activities in numerous tissues and cells, such as growth hormone-stimulated growth, metabolism and protein translation. Due to its participation in the GH-IGF1 axis it contributes among other things to the maintenance of muscle strength, muscle mass, development of the skeleton and is a key factor in brain, eye and lung development during fetal development. Studies have shown the importance of the GH/IGF1 axis in directing development and growth, where mice with an IGF1 deficiency had a reduced body- and tissue mass. Mice with an excessive expression of IGF1 had an increased mass.
Due to the immune response, LTLs can experience the accelerated blood clearance (ABC) phenomenon. This phenomenon is more common in repeated dosage usage of LTLs, such as multi-dose PEGylated formulas, because of immunological memory. The pharmokinetics and clearance rates of the second dose have been shown to be significantly reduced while accumulation in the spleen and liver increases. This poses challenges for clinical applications of LTLs that require multiple doses to be effective. Ligand-targeted liposomes need specific conditions to remain intact for use. Controlling environmental factors such as temperature and pH is necessary to maintain the integrity of the molecules. This can be helpful for temperature-sensitive or pH-dependent drug release conditions but is harmful if the pH changes at an inopportune time. This technology can also be used in combination with enzymes such as in Gal-Dox, which releases active doxorubicin in combination with β-Galactosidase. Making sure the compound does not encounter the enzyme too early is also important for effective usage. There is a possibility that LTLs lead to immunosuppression. LTLs are cleared through the RES which is part of the innate immune system. Macrophage saturation to remove the liposomes could impact the ability of the phagocytic cells to function properly to conduct immune functions. Significant immune suppression has not been observed in clinical cases for therapeutic doses of LTLs containing non-cytotoxic drugs.
The desorption electrospray ionization (DESI) was the first-MS technique, which allowed non-invasive testing of any objects (or organisms) without sample preparation, regardless of their shape or mechanical properties.
=== Names === Pizotifen is the generic name of the drug and its INNTooltip International Nonproprietary Name and BANTooltip British Approved Name, while pizotyline is its USANTooltip United States Adopted Name. Brand names of pizotifen include Sandomigran, Mosegor, and Litec, among others.
=== Race and ethnicity === Given that the research for BED is not supported on the topic of ethnicity, it makes it difficult to understand how common BED is. However, the racial makeup of BED distinctly varies from anorexia nervosa and bulimia nervosa. BED has the same effect no matter the color of someone's skin. Many studies surround BED being focused on white women. One literature review found information citing no difference between BED prevalence among Hispanic, African American, and White women while other information found that BED prevalence was highest among Hispanics followed by Black individuals and finally White people. A 2021 study has observed "higher rates of BED as compared to other ethnic groups" for African Americans. The likelihood of reporting eating disorder symptoms is also lower in some groups, including African Americans. Asian-Americans also face decreased reporting of ED symptoms. This can be partly attributed to "significantly higher thin-ideal internalization" compared to other ethnic groups. Migration can also influence BED risk. Mexican-American immigrants have been observed to face a greater risk of BED following migration.
Sources: en.wikipedia.org
== Synopsis == The process of separating mixtures of chemical compounds by passing them through a column that contains a solid stationary phase that was eluted with a mobile phase (column chromatography) was well known at that time. Chromatographic separation was considered to occur by an adsorption process whereby compounds adhered to a solid media and were washed off the column with a solvent, mixture of solvents, or solvent gradient. In contrast, Martin and Synge developed and described a chromatographic separation process whereby compounds were partitioned between two liquid phases similar to the separatory funnel liquid-liquid separation dynamic. This was an important departure, both in theory and under equilibrium conditions. Martin and Synge initially designed a sequential liquid-liquid extraction with serially connected glass vessels that functioned as separatory funnels. The seminal article presenting their early studies described a rather complicated instrument that partitioned amino acids between water and chloroform solvents. The process was termed "counter-current liquid-liquid extraction." Martin and Synge described the theory of this technique in reference to the continuous fractional distillation described by Randall and Longtin. They deemed this approach too cumbersome, so they developed a new method. One solvent, such as water, is immobilized by absorption onto silica gel particles as the stationary phase. The other solvent, such as chloroform, is the mobile phase. They published this method in 1941.
=== Mutualists === Certain bacteria form close spatial associations that are essential for their survival. One such mutualistic association, called interspecies hydrogen transfer, occurs between clusters of anaerobic bacteria that consume organic acids, such as butyric acid or propionic acid, and produce hydrogen, and methanogenic archaea that consume hydrogen. Without the archaea, the bacteria in this association would be unable to continuously consume the organic acids, as this reaction produces hydrogen that would accumulate in their surroundings. Only the intimate association with the hydrogen-consuming archaea keeps the hydrogen concentration low enough to allow the bacteria to grow.
3 WBr5 + Al thermal gradient→475 °C → 240 °C 3 WBr4 + AlBr3 2 EuBr3 + H2 → 2 EuBr2 + 2 HBr 2 TaBr4 500 °C→ TaBr3 + TaBr5 Most metal bromides with the metal in low oxidation states (+1 to +3) are ionic. Nonmetals tend to form covalent molecular bromides, as do metals in high oxidation states from +3 and above. Both ionic and covalent bromides are known for metals in oxidation state +3 (e.g. scandium bromide is mostly ionic, but aluminium bromide is not). Silver bromide is very insoluble in water and is thus often used as a qualitative test for bromine.
=== BsAbs on the market === Several bispecific antibodies are presently in clinical use. Blinatumomab, which targets CD19 and CD3, is used in the treatment of Philadelphia chromosome negative B cell acute lymphoblastic leukemia (ALL). Emicizumab, which targets clotting factors IXa and X, is used in the treatment of hemophilia A. Catumaxomab was withdrawn from the European market in 2017 for commercial reasons. Amivantamab, which targets epidermal growth factor (EGF) and MET receptors, for adult patients with locally advanced or metastatic non-small cell lung cancer (NSCLC) with epidermal growth factor receptor (EGFR) exon 20 insertion mutations. Teclistamab, which targets CD3 and B-cell maturation antigen (BCMA), is used in the treatment of multiple myeloma, and zenocutuzumab.
Sources: en.wikipedia.org
Dry powder is normally held at -20 °C or lower, away from light and moisture. Sealed vials can also be kept at 2-8 °C for shorter intervals. Warming to room temperature before opening prevents condensation.
In solution, hydrolysis of peptide bonds and oxidation of the methionine residue are the principal concerns. Oxidation converts methionine to its sulfoxide form, shifting the mass by sixteen daltons. Both processes are slowed by cold storage and by avoiding alkaline conditions.
A certificate documents what the supplier measured on a specific lot, not how a laboratory will use the material. Independent verification of identity and purity is common practice. Acceptance criteria should be defined before a batch is ordered.
Semax is a synthetic seven-amino-acid peptide derived from a fragment of corticotropin. It is used in Russia as a nasal preparation, while elsewhere it is studied as a research compound. It is not approved as a medicine in most countries.